Managing Callouts

Synapse provides a callout editor for lesions, aneurysms, thrombi, and NIV segments, which enables you to quickly edit data directly on the diagram. Using the various options provided, you can use the callout editor to show, hide, or edit data in the callout.

Note:

  • Callouts display by default and are read-only.
  • Callouts can only be edited using the callout editor.
  • Date and time controls are not supported in callouts.
  • When moving a lesion to another segment that does not offer the existing stenosis value in the drop-down list, the stenosis value in the callout editor and the properties panel will be empty.

Steps

  • Select one of the following options to display, hide, or edit a callout.

If you want to do this ...

Complete these steps ...

Show or hide a lesion, aneurysm, pseudoaneurysm, thrombus, or NIV segment callouts.

  • Click Show/Hide , located on the corresponding properties panel section to show or hide a callout.

Open the callout editor.

  • Click an existing callout to open the callout editor.

Close the callout editor.

  • Click the Esc key or click anywhere in the vessel diagram to close the callout editor.
  • Note: Click outside the callout editor to close it.

Edit an NIV segment callout.

  • Click the NIV callout to open the callout editor.
  • Use the configured options to add or edit information.
    • All data configured to display in the callout automatically displays if present in the properties panel.
    • Any edits that you apply using the callout editor will automatically update the segment properties in the properties panel.
    • With the exception of the PSV/EDV, you can add or remove any property from the callout, using the Show/Hide icons in the callout editor.
  • Note:
    • Callouts always display if a PSV or EDV is included.
    • You cannot turn off velocity information using the callout editor.
    • As an option, click Show/Hide in the properties panel to hide the entire callout.

Edit a lesion, pseudoaneurysm, or thrombus callout.

  • Click the lesion, pseudoaneurysm, or thrombus callout to display the callout editor.
  • Use the configured options to edit properties.
    • All data configured to display in the callout automatically displays if present in the properties panel.
  • NIV, Cath, and PV callout properties differ, depending on the diagram.
  • Any edits that you apply using the callout editor will automatically update the properties in the properties panel.
  • If a treatment is added to a lesion, the callout updates accordingly to display both pre-stenosis and post-stenosis treatment data. This information cannot be hidden.
  • Optional: Click Show/Hide , located on the properties panel to hide the callout.

Related Topics

Carrying Over Vessel Diagram Data

Changing a Prior Stent to a Current Stent

Deleting Vessel Diagram Figures